Produkter 0
5531A
 
 

5531A

 

Loop-powered LCD indicator

 

  • 4 digit 1/8 DIN (48 x 96 mm) loop-powered LCD display
  • Easy push-button configuration
  • Backlit LCD display is readable in low light conditions
  • Display can be mounted in the safe area or in I.S. / Ex zone 2
  1. Overview +

  2. Technical details +

  3. Accessories +


Application

  • The 5531 indicator is powered by the 4 to 20 mA current loop and is easily scaled to display the correct process value.
  • Because it does not require separate power wiring, the 5531 is perfect for remote display of process loops.
  • The 5531A display can be panel mounted in the safe area or I.S. / Ex Zone 2 (gas).

Technical characteristics

  • With a full measurement range of 3.6 to 23 mA, the 5531 is NAMUR NE43 compliant.
  • The display can be push-button scaled to any range between -9999 to 9999, and reverse display action is possible.
  • The LCD backlight can be set to half or full intensity for easy viewing in low light conditions.
  • The display only requires 1.5 VDC, (75 Ω loop load), with the backlight turned off.
  • The input is HART transparent.
  • The front push-buttons can be disabled to prevent unauthorized adjustment.

Mounting / installation

  • Once panel mounted with the included gasket, the 5531 provides IP65 ingress protection.

Environmental Conditions

Operating temperature -20°C to +60°C
Storage temperature -20°C to +60°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP65, from front

Mechanical specifications

Dimensions (HxWxD) 48 x 96 x 120 mm
Cut out dimensions 44.5 x 91.5 mm
Weight approx. 200 g
Wire size, connector terminal 1 - 4 0.13...2.08 mm2 / AWG 26...14 stranded wire
Screw terminal torque 0.5 Nm
Cable glands and cable diameter M16 x 1.5 / Ø 5...8 mm

Common specifications

Supply

Supply voltage Input loop-powered

Response time

Response time (0...90%, 100...10%) < 1 s
Signal / noise ratio > 60 dB
Updating time 500 ms
EMC immunity influence < ±0.5% of span

Input specifications

Current input

Loop error detection, 4...20 mA: Low ~ < 3 mA
Loop error detection, 4...20 mA: High ~ > 24 mA
Input range 4...20 mA
Measurement range 3.6...23 mA
Input voltage drop, without backlight < 1.5 V @ 20 mA
Input voltage drop, with full backlight < 10.5 V @ 20 mA

Observed authority requirements

LVD 2014/35/EU
EMC 2014/30/EU
EAC TR-CU 020/2011

Output specifications

Display

Display readout ± 9999 (4 digits)
Digit height 16 mm

Approvals

ATEX 2014/34/EU KEMA 05ATEX1044 X (5531A/B1)
Din anmodning om et tilbud er nu sendt til os. - 0 Produkter på din liste
Produktbeskrivelse Antal
Anfør venligst produktvariant - (se data ark på produktsiden). Eller anfør "variant ukendt".
Din kontaktinformation
Fortsæt med at browse
Du har ikke tilføjet produkter til listen
Du har ikke tilføjet nogen produkter...

På vores produktsider har du mulighed for at klikke på "FÅ ET TILBUD" knappen og tilføje produktet til en liste - og sende listen til os.
Når du sender listen, anmoder du om at få et uforpligtende tilbud på de listede produkter.

Når du har sendt listen, vender vi tilbage til dig så hurtigt som muligt.

Har du ikke indsendt listen, vil du kunne se den i 7 dage her på hjemmesiden (vi lægger en cookie på din pc eller tablet).

Vi håber, du får glæde af funktionaliteten. Gå til produktsiderne for at tilføje produkter til din liste.

Tak for din forespørgsel.
Vi vil kontakte dig per telefon eller email så hurtigt som muligt.