Produkter 0
5531B
 
 

5531B

 

Loop-powered LCD indicator

 

  • 4 digit 1/8 DIN (48 x 96 mm) loop-powered LCD display
  • Easy push-button configuration
  • Backlit LCD display is readable in low light conditions
  • Display can be mounted in the safe area or in I.S. / Ex zone
  1. Overview +

  2. Technical details +

  3. Accessories +


Application

  • The 5531 indicator is powered by the 4 to 20 mA current loop and is easily scaled to display the correct process value.
  • Because it does not require separate power wiring, the 5531 is perfect for remote display of process loops.
  • The 5531B can be mounted in Ex Zone 1.
  • The 5531B1 Ex display includes the 8501 enclosure and can be mounted in Ex Zone 2 or 22 (gas or dust).
  • The 5531B2 includes the 8501 enclosure and can be mounted in Ex Zone 1, 2, 21 or 22 (gas or dust).

Technical characteristics

  • With a full measurement range of 3.6 to 23 mA, the 5531 is NAMUR NE43 compliant.
  • The display can be push-button scaled to any range between -9999 to 9999, and reverse display action is possible.
  • The LCD backlight can be set to half or full intensity for easy viewing in low light conditions.
  • The display only requires 1.5 VDC, (75 Ω loop load), with the backlight turned off.
  • The input is HART transparent.
  • The front push-buttons can be disabled to prevent unauthorized adjustment.

Mounting / installation

  • Once panel mounted with the included gasket, the 5531 provides IP65 ingress protection.

Environmental Conditions

  • Operating temperature

    -20°C to +60°C

  • Storage temperature

    -20°C to +60°C

  • Calibration temperature

    20...28°C

  • Relative humidity

    < 95% RH (non-cond.)

  • Protection degree

    IP65, from front

Mechanical specifications

  • Dimensions (HxWxD)

    48 x 96 x 120 mm

  • Cut out dimensions

    44.5 x 91.5 mm

  • Weight approx.

    200 g

  • Cable glands and cable diameter

    M16 x 1.5 / Ø 5...8 mm

  • Wire size, connector terminal 1 - 4

    0.13...2.08 mm2 / AWG 26...14 stranded wire

Common specifications

  • Supply

  • Supply voltage

    Input loop-powered

  • Response time

  • Response time (0...90%, 100...10%)

    < 1 s

  • EMC immunity influence

    < ±0.5% of span

  • Signal / noise ratio

    > 60 dB

  • Updating time

    500 ms

Input specifications

  • Current input

  • Measurement range

    3.6...23 mA

  • Loop error detection, 4...20 mA: Low

    ~ < 3 mA

  • Loop error detection, 4...20 mA: High

    ~ > 24 mA

  • Input voltage drop, without backlight

    < 1.5 V @ 20 mA

  • Input voltage drop, with full backlight

    < 10.5 V @ 20 mA

Output specifications

  • Display

  • Display readout

    ± 9999 (4 digits)

  • Digit height

    16 mm

Observed authority requirements

  • EMC

    2014/30/EU

  • EAC

    TR-CU 020/2011

Approvals

  • ATEX 2014/34/EU

    KEMA 05ATEX1044 X (5531A/B1)

    KEMA 05ATEX1105 X (5531B/B2)

  • EAC Ex TR-CU 012/2011

    RU C-DK.GB08.V.00410

Din anmodning om et tilbud er nu sendt til os. - 0 Produkter på din liste
Produktbeskrivelse Antal
Anfør venligst produktvariant - (se data ark på produktsiden). Eller anfør "variant ukendt".
Din kontaktinformation
Fortsæt med at browse
Du har ikke tilføjet produkter til listen
Du har ikke tilføjet nogen produkter...

På vores produktsider har du mulighed for at klikke på "FÅ ET TILBUD" knappen og tilføje produktet til en liste - og sende listen til os.
Når du sender listen, anmoder du om at få et uforpligtende tilbud på de listede produkter.

Når du har sendt listen, vender vi tilbage til dig så hurtigt som muligt.

Har du ikke indsendt listen, vil du kunne se den i 7 dage her på hjemmesiden (vi lægger en cookie på din pc eller tablet).

Vi håber, du får glæde af funktionaliteten. Gå til produktsiderne for at tilføje produkter til din liste.

Tak for din forespørgsel.
Vi vil kontakte dig per telefon eller email så hurtigt som muligt.