Ricerca prodotto

Temperature

5335
2-wire transmitter with HART® protocol

PR electronics’ temperature transmitters cover every application within transmission of RTD and TC sensor signals into mA, mV, HART, PROFIBUS® PA and FOUNDATION™ Fieldbus communication. The product range includes:

  • PRetrans 5100
  • PRetop 5300
  • PRetrans 6300
  • The 2200 series

 

PRetrans 5100, PRetop 5300 and PRetrans 6300

With the unique AUTOSWITCH, which automatically recognises the protocol to which the transmitter is connected, these temperature transmitters can be integrated in both PROFIBUS® PA and FOUNDATION™ Fieldbus systems.

  • The digital communication permits the user to carry out differential, redundancy and average measurements, PID regulation, diagnostics, etc.
  • The integrated calibration function allows set up of sensor error detection.
  • The transmitters are available for both standard and I.S. applications.
  • The transmitters are most flexible and configurable through PR electronics’ own PC program, PReset, or the common bus systems dependant on transmitter type.

 

PRetop 5350 and PRetrans 6350 

  • Bus transmitters compatible with the PROFIBUS® PA and FOUNDATION™ Fieldbus protocols.
  • Level transmitters for Ohmic level sensors with potentiometers up to 100 kOhm with the standardised bus protocols PROFIBUS® PA and FOUNDATION™ Fieldbus as output.
  • LAS function and PID are both integrated in the FOUNDATION™ Fieldbus transmitter. 
  • PRetop 5350 and PRetrans 6350 are available as standard or I.S. versions. 
  • PRetop can be mounted in DIN form B sensor head and thus suitable for direct mounting at the measurement area.
  • The PRetrans 6350 is for DIN rail mounting and is thus appropriate for mounting in control room.

 

The 2200 series

A number of low-priced temperature transmitters each covering a specific application make up the 2200 series. Some transmitters are configured from factory; others can be programmed wholly or partly through DIP-switches or front/display.

 

Order brochures

2202Trasmettitore R/I
Zoccolo undecal (11 poli)
2271Trasmettitore R/I / soglia di allarme
Zoccolo undecal (11 poli)
2273Trasmettitore R/I a 2 fili
Zoccolo undecal (11 poli)
2914Trasmettitore di temperatura autoalimentato
A parete
5102Trasmettitore programmabile RTD a 2 fili
Barra DIN
5131ATrasmettitore programmabile a 2 fili
Barra DIN
5331ATrasmettitore programmabile a 2 fili
Testa del sensore DIN B
5331DTrasmettitore programmabile a 2 fili
Testa del sensore DIN B
5333ATrasmettitore programmabile a 2 fili
Testa del sensore DIN B
5333DTrasmettitore programmabile a 2 fili
Testa del sensore DIN B
5334ATrasmettitore programmabile a 2 fili
Testa del sensore DIN B
5334BTrasmettitore programmabile a 2 fili
Testa del sensore DIN B
5335ATrasmettitore programmabile a 2 fili con protocollo HART
Testa del sensore DIN B
5335DTrasmettitore programmabile a 2 fili con protocollo HART
Testa del sensore DIN B
5350ATrasmettitore PROFIBUS PA / FOUNDATION Fieldbus
Testa del sensore DIN B
5350BTrasmettitore PROFIBUS PA / FOUNDATION Fieldbus
Testa del sensore DIN B
6331ATrasmettitore programmabile a 2 fili
Barra DIN
6331BTrasmittitore programmabile a 2 fili
Barra DIN
6333ATrasmettitore programmabile a 2 fili
Barra DIN
6333BTrasmettitore programmabile a 2 fili
Barra DIN
6334ATrasmettitore programmabile a 2 fili
Barra DIN
6334BTrasmettitore programmabile a 2 fili
Barra DIN
6335ATrasmettitore HART a 2 fil
Barra DIN
6335DTrasmettitore HART a 2 fil
Barra DIN
6350ATrasmettitore Profibus PA / Foundation Fieldbus
Barra DIN
6350BTrasmettitore Profibus PA / Foundation Fieldbus
Barra DIN