I.S. Interfaces

5104
Ex repeater/
power supply

Intrinsic safety, I.S., interfaces are implemented between the process sensors and the major control system. The transmitted signal from the I.S. interfaces can be analogue, digital or HART®.

PR electronics’ I.S. interfaces are marketed worldwide and designed to meet the terms of the strictest international standards from the processing industry. Thus, the modules for I.S. signal conditioning comply with both European and American standards.  

ATEX is the name of a European directive concerning material for hazardous atmospheres. The I.S. interfaces are adapted to this directive and meet the demands of the EN 50014, EN 50020 and EN 50282-1-1. Thus, the I.S. interfaces are certified to function as associated equipment for potential hazardous atmospheres. According to the ATEX directive the I.S. interfaces from PR electronics can function in the following potential hazardous areas:

  • Group 2 (surface industry)
  • Zones: Zones 0, 1, 2 for inflammables gas, mists and vapors as well as Zones 20, 21, 22 for inflammable dust.

Furthermore, several of the I.S. interfaces are certified according to UL 913 - the American I.S. standard. These modules can be used in connection with the following areas:

  • Class I, Division 1, Group A, B, C, D; Zone 0 & 1, Group II C (gas)
  • Class II, Division 1, Group E, F, G (dust)

The universal uniqueness of the 5000B series offers the customer many concrete advantages:

  • Alarm functions for cable and sensor errors for process optimisation.
  • Quick response time optimising the process.
  • Technology making the I.S. ground connection unnecessary.
  • Transmission of HART® signals with high galvanic isolation.
  • Diagnosis via AMS function.

 

Order brochures

5104BRipetitore / alimentatore per zona Ex
Barra DIN
5105BTrasmettitore analogico per zona Ex
Barra DIN
5106BRipetitore con trasparenza HART
Barra DIN
5107BDriver con trasparenza HART
Barra DIN
5114BTrasmettitore programmabile
Barra DIN
5115BCalcolatore di segnale
Barra DIN
5116BTrasmettitore programmabile
Barra DIN
5131BTrasmettitore programmabile a 2 fili
Barra DIN
5202BBarriera Ex per impulsi
Barra DIN
5203BTrasmettitore digitale per zona Ex
Barra DIN
5223BConvertitore f/I-f/f programmabile
Barra DIN
5420BAlimentatore per zona Ex
Barra DIN
9113Convertitore di temperatura / mA
Barra DIN
9116Convertitore universale
Barra DIN
9202Barriera per impulsi
Barra DIN
9203Driver per valvole / allarme
Barra DIN