Búsqueda de producto

Temperature

5335
Transmisor de 2 hilos con protocolo HART®

PR electronics’ temperature transmitters cover every application within transmission of RTD and TC sensor signals into mA, mV, HART®, PROFIBUS® PA and FOUNDATION™ Fieldbus communication. The product range includes:

  • PRetrans 5100
  • PRetop 5300
  • PRetrans 6300
  • The 2200 series

 

PRetrans 5100, PRetop 5300 and PRetrans 6300

  • The unique AUTOSWITC function, which automatically recognises the protocol to which the transmitter is connected, allows these temperature transmitters to be integrated in both PROFIBUS® PA and FOUNDATION™ Fieldbus systems.
  • The digital communication permits the user to carry out differential, redundancy and average measurements, PID regulation, diagnostics, etc.
  • The integrated calibration function allows setup of sensor error detection.
  • The transmitters are available for both standard and I.S. applications.
  • The transmitters are most flexible and configurable through PR electronics’ own PC program, PReset, or the common bus systems dependant on transmitter type.

 

PRetop 5350 and PRetrans 6350 

  • Bus transmitters compatible with the PROFIBUS® PA and FOUNDATION™ Fieldbus protocols.
  • Level transmitters for Ohmic level sensors with potentiometers up to 100 kOhm with the standardised bus protocols PROFIBUS® PA and FOUNDATION™ Fieldbus as output.
  • LAS function and PID are both integrated in the FOUNDATION™ Fieldbus transmitter. 
  • PRetop 5350 and PRetrans 6350 are available as standard or I.S. versions. 
  • PRetop can be mounted in DIN form B sensor head and thus suitable for direct mounting at the measurement area.
  • The PRetrans 6350 is for DIN rail mounting and is thus appropriate for mounting in control room.

 

The 2200 series

A number of low-priced temperature transmitters each covering a specific application make up the 2200 series. Some transmitters are configured from factory; others can be programmed wholly or partly through DIP-switches or front/display.

 

Order brochures

 

2202Transmisor R/I
Base de 11 patillas
2271Transmisor R/I / amplificador con salida de relé
Base de 11 patillas
2273Transmisor R/I de 2 hilos
Base de 11 patillas
2914Transmisor de 2 hilos de temperatura ambiente interior
En pared
5102Transmisor RTD
Carril DIN
5131ATransmisor de 2 hilos programable
Carril DIN
5331ATransmisor de 2 hilos rogramable
Cabezal de sensor DIN B
5331DTransmisor de 2 hilos programable
Cabezal de sensor DIN B
5333ATransmisor de 2 hilos programable
Cabezal de sensor DIN B
5333DTransmisor de 2 hilos programable
Cabezal de sensor DIN B
5334ATransmisor de 2 hilos programable
Cabezal de sensor DIN B
5334BTransmisor de 2 hilos programable
Cabezal de sensor DIN B
5335ATransmisor de 2 hilos con protocolo HART
Cabezal de sensor DIN B
5335DTransmisor de 2 hilos con protocolo HART
Cabezal de sensor DIN B
5350ATransmisor PROFIBUS PA / FOUNDATION Fieldbus
Cabezal de sensor DIN B
5350BTransmisor PROFIBUS PA / FOUNDATION Fieldbus
Cabezal de sensor DIN B
6331ATransmisor de 2 hilos programable
Carril DIN
6331BTransmisor de 2 hilos programable
Carril DIN
6333ATransmisor de 2 hilos programable
Carril DIN
6333BTransmisor de 2 hilos programable
Carril DIN
6334ATransmisor de 2 hilos programable
Carril DIN
6334BTransmisor de 2 hilos programable
Carril DIN
6335ATransmisor HART de 2 hilos
Carril DIN
6335DTransmisor HART de 2 hilos
Carril DIN
6350ATransmisor Profibus PA / Foundation Fieldbus
Carril DIN
6350BTransmisor Profibus PA / Foundation Fieldbus
Carril DIN